Pentair easy touch not communicating with pump

Update - I got help from Pentair tech support (thanks to reading another posting in this forum, I found that such a thing exists). It's probably due to the antenna circuit board needing replaced. The Intellitouch unit won't work in "Auto" mode if it can't communicate with the antenna - even the buttons on the control panel won't work if that is ....

The pump just isn't being ran long enough or the chlorine output is too low, or the pool is not being shocked as needed. ... The only other time I have seen the salt level at zero on the panel or ScreenLogic was when the cell was not communicating with the EasyTouch.. But, if you can change the % on the ET and the cell changes that means at ...With SunTouch, your pump and heater automatically run whenever you want, for as long as you want, so your pool and spa are always warm and inviting. Or, switch to manual mode for those spontaneous plunges. Either way, you're in complete control. One-touch function—no complicated routine to memorize. Ability to program pool and spa and 2 ...Easy Touch 4P (520591) Does anyone know how or if it is possible to connect a Pentair 3HP Intelliflo VSF pump and a 1.5HP Superflo VS to the Easy Touch control unit? Right now I have the 3HP VSF connected with the included 2 conductor com cable to the com terminal in the Easy Touch. That makes perfect sense.

Did you know?

Introducing the Pentair Home App. Stay smart, connected and protected with the Pentair Home app; offering a range of connected products that give you command of your home's water. From filter to flow, tap to pool, shower to sump pump, we help you move, improve and enjoy your water, with peace of mind at your fingertips.Incorrect connection of wiring may damage heat pump or the pool/spa equipment. Damage to equipment caused by incorrect wiring connections is not covered under the equipment warranty. If uncertain of the correct wiring methods, contact AquaCal Technical Support Group before continuing installation: (727) 823-5642.Page 25: Lights Menu. From the Lights screen you can manually switch all lights on or off, and synchronize colored lights. Up to eight (8) lights (EasyTouch 8) or 4 lights (EasyTouch 4) can be independently controlled from the Lights screen. Each light requires a separate auxiliary relay circuit.

Plug the AC adapter into an AC wall outlet. Insert the AC Adapter plug into the bottom of the cradle. Place the MobileTouch controller in the cradle. Note: When the MobileTouch controller is placed in the cradle the display and backlight will be on. After five minutes the backlight will shut off.Salt Water Generator. SWG Type. Pentair Intellichlor IC-40. Sep 13, 2020. #1. When we initially installed the ScreenLogic setup, I used my phone to connect to it remotely (ie: I shut my phone's WiFi off, and connected over the WWW VIA the cell network), and it worked fine to connect and run through initial config and also to control the pump ...MYSELF do a latest Pentair EasyTouch PL4 that currently only running the pump and the pool light. The pool light books on the schedule just subtle, but and pump execution continuously when in Auto manner. It does not follow that schedule. I entered a schedule for Pool furthermore used all the default settings. Is...Page 46: Drive Assembly Removal And Installation. Drive Assembly Removal and Installation To remove the IntelliFlo ® VF Variable Flow Pump drive and control panel from the motor assembly: 1. Make sure all electrical breakers and switches are turned off before removing the drive. 2. Disconnect the communication cable from the IntelliFlo pump.1 Installation Guide. 2 Easytouch 8 and 4 Pool and Spa Control System Kit Contents. 3 Easytouch Load Center High Voltage Connections. 4 Easytouch Motherboard Connections. 5 Installing Auxiliary Relays. 6 Easytouch System Start-Up. 7 Easytouch System Wiring Diagram. Download this manual. EasyTouch.

If you have any questions please contact us through our website at: https://www.poolspecialists.com/Share. shartson. • 2 yr. ago. I am trying to configure a used Pentair intelliconnect. I think I got the box on Wi-Fi as the light stays green. But when I try to add the device to the Pentair Home app, it says it is in service mode. I do not have it in service mode. It is in auto mode. It keeps saying that and won't add. ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Pentair easy touch not communicating with pump. Possible cause: Not clear pentair easy touch not communicating with pump.

I have a Pentair EasyTouch control system and a STA-Rite Intellipro VSF pool pump. A week ago I would notice the pump was not running. Went to the EasyTouch control box and noticed that the pool filter breaker had tripped. I reset the breaker and it would trip almost immediately.Our Pentair pool heater troubleshooting guide will have your heater up and running in no time! ... Service pump and/or filter. Service heat exchanger. Correct water chemistry. Service bypass valve. ... Feel free to leave us a message and we will be in touch as soon as an agent is available. For urgent questions, you can reach us directly at 1 ...

I on one new home owner with an four year vintage system and mys EasyTouch system is not turning off the pump on schedule and will not suffer me bend it off from the remote. EGO has to switch from Motor mode to Service mode to turn it shut. ... Pentair EasyTouch not turning pump off on schedule Pentair EasyTouch don turning power off on ...7. The system will reset all settings to the factory defaults. Please note that resetting your pentair easy touch will erase all customized settings. It’s important to reconfigure the system according to your preferences after the reset. Conclusion. To sum up, the communication loss of the pentair pump 1 can be a frustrating issue for users.

paul henney funeral home Both systems can even help you save on energy costs because with automatic scheduling, you don't have to rely on memory or limited time clocks to turn off equipment. Control System Kit Includes. (1) EasyTouch PL4 Control Panel (Mounted in the Power Center) (1) Power Center Enclosure. (1) ScreenLogic® Wireless Kit. 800 327 8543marisa pitman warren hampton sc Learn how to connect an EasyTouch automation system to an IntelliFlo variable speed pump in this video tutorial. You will see the steps and settings required to make the connection and control the ...So as I press and filter pump button, the pink LED on front of button turns on, POOL appears on easy touch display, but pump doesn't turn on and pump panel states display did active. Whenever I print which vacuum pump button, the vacuum pump comes to plus the intelliflo pump comes on. The intelliflo... brenda's inferno by the armadillo grill phoenix reviews Nov 5, 2012 · Posted November 5, 2012. Pool equipment was running on automated settings via Easy Touch control panel. Equipment stopped working. Switched to service mode to operate equipment manually and the main pump and booster pump won't turn on, but the falls pump will turn on manually. Quote.The new IntelliComm II Interface Adapter provides automatic control of IntelliPro® and IntelliFlo® variable speed and flow pumps with Pentair® Compool® systems, as well as Jandy* and Hayward* automation controllers. Easy installation—low-voltage protocol adapter works with Compool and other control systems and draws power from the ... vacation lodge pigeon forge bed bugsjuul light meaninguber eats promo existing users Step One: Go to the settings logo on your touch screen panel. One here, you want to scroll down tot he bottom of the list to "Pentair User Portal". Once here you will click on the "Enable Web and Mobile Interface". This is important to do first to ensure your Intellicenter is able to locate a wireless network when setting up.The old sensor is likely 5/16-inch, and the new sensor will not fit. 1. The existing water sensor will be located between the filter pump and the primary filter. Remove the sensor. 2. Drill a 3/8-inch hole in the 3-inch or 2-inch pipe. 3. Position the hose clamp over the replacement sensor and gently tighten around pipe. Do not overtighten ... vijay rao ihuman Jan 30, 2019 ... How To Program IntelliFlo Pumps on Pentair's Easy Touch Automation - Chlorine King. Chlorine King Pool Service•17K views · 11:03. Go to channel ... indoor swap meet rialto camovie theatre bemidji mnaa 2148 flight status The EasyTouch®PL4/PSL4 Control Systems Power Center system transformer can be wired for 120 VAC at 2AMP 50/60 Hz (factory installed) or 240 VAC at 1AMP 50/60 Hz. The system transformer is pre-wired at the factory for 120 VAC service. To rewire the system transformer and for 240 VAC: 1.The Suntouch controller talks to the Intelliflo pump through a serial comm link, RS 485. The power goes directly to the pump and turns on by serial command from the controller. I think the relay inside the pump is fine since I can turn it on manually at the pump built in panel.